Interlock Alarm
Описание ошибки Interlock Alarm:
Occurs when the Interlock is disconnected.
Как устранить ошибку Interlock Alarm:
Short the Interlock pins and restart the laser to try. If this error continues to occur, please contact Raycus.
Laser Out Alarm
Описание ошибки Laser Out Alarm :
1. Laser Out Alarm immediately occurs when the laser is powered.
The laser will auto-lock after two times of this error occurs successive, please contact Raycus.
2. The laser will get this error when it does not emit with correct settings.
Как устранить ошибку Laser Out Alarm:
Close the shutter and pop up the “LASER” button on the front panel of the laser to check if the red guide light is output normally when it isn’t emitting. If there is no red guide light, please stop using the laser immediately and contact Raycus. If the red guide light output normally, please restart the laser to try, if the alarm continues to occur, please contact Raycus.
Laser Power Alarm
Описание ошибки Laser Power Alarm :
The alarm is generated when the emission of the laser cannot reach the set value. Power error occurs only when the laser is emitting.
Как устранить ошибку Laser Power Alarm :
Restart the laser, if this error continues to occur, please contact Raycus.
T1/T2 Alarm
Описание ошибки T1/T2 Alarm :
Low temperature/high temperature alarm of the laser. The sensor in the laser detects an abnormal temperature inside the laser. A high-temperature / low-temperature error occurs when the temperature at the monitoring point exceeds the set upper / lower limit.
Как устранить ошибку T1/T2 Alarm :
High temperature alarm, please check if the water-cooling system is normally working, the water temperature is set correctly, and the water connection is correct. When the water cooling system works normally and the water temperature drops below 30°C, restart the laser. If the alarm continues, please contact Raycus.
Hum Alarm
Описание ошибки Hum Alarm:
The Hum Alarm of the laser, the internal temperature of the laser detects that the current water-cooled plate temperature is lower than the internal dew point temperature, and there is a risk of condensation.
Как устранить ошибку Hum Alarm:
Immediately stop using the laser. For RFL-C100~RFL-C1000, please improve the working environment and after the ambient temperature is lower than internal temperature of the laser, restart the laser (advice to configure alone Air-conditioned room for the laser). For RFL-C100~RFL-C1000, please wait for the air conditioner to run for 30 minutes before restart the laser. If the alarm continues to occur, please contact Raycus.